H & H Surgical Technologies

We offer a wide variety of used endoscopic and general medical equipment,
new and used laparoscopic instrumentation and surgical products, and extensive repair capabilities to hospitals, veterinarians and dealers at low prices.

Skip Navigation LinksHome >> Products >> Defibrillators

All Categories
  Video Laparoscopy
  Surgical Instruments
  Flexible Endoscopy
  Urology
  Arthroscopy
  Electrosurgical Units
  Defibrillators
  Disposables
  Orthopedic
  Veterinarians
  Discounted Combinations
Defibrillators
« Previous 1 Next »
PHYSIO CONTROL LIFEPAK 9A Defibrillator

Physiocontrol Lifepak 9A Cardiac monitor defibrillator "The Lifepak 9A Defibrillator/pacemaker is a complete cardiac life support system for crash carts needs. Used by Hospital staff and other authorized health Care Providers" - Esta ofertando por este excelente Desfibrilador Physiocontrol Modelo Lifepak 9A En perfectas condiciones de funcionamiento, viene con manual de instrucciones en formato .pdf Se encuentra en perfectas condiciones de uso y apariencia!

$600.00 - details »
DataScope Passport EL Monitor w/accs. PATIENT READY!

Datascope Passport EL monitor. A versatile vital signs monitor specifically designed for surgery, bedside and transport applications. The large, easy-to-read display provides up to three waveforms. The Passports easy-to-understand menu and single dedicated function keys make them fast and easy-to-use. Featuring ECG, NIBP, pulse oximetry, respiration, temp and recorder. Light weight and portable, the Passport is a perfect device for multi-parameter monitoring needs. Datascope Passport EL Patient Monitor Product Overview Key Features of the Passport EL Monitor are: ??? Compact bedside and transport use for maximum monitoring flexibility ??? Adult to neonatal capability with respiration ??? Fast response CO 2 sensor verifies intubation and allows clinical as- sessment of ventilation ??? Single function keys for ease of use ??? List trend of up to 120 measure- ments to aid recordkeeping and easy review of patient data ??? Alarm status is instant and simple ??? Unique Datasette replaceable cartridge makes software enhance- ments fast and easy Specifications: Dimensions:..9.5 inches H x 13 inches W x 8 inches L maximum Weight:....................13 lbs Maximum without batteries Power Requirements: Power consumption:..........................15 Watts typical Voltage input:...............100, 120, 220, 240 VAC ??10% Mains frequency 47 to 65 Hz ECG:.........................................................Leads: I, II, III Display sensitivity: 0.25, 0.5, 1.0, 2.0, 3.0, 4.0 cm/mV ??10%. Frequency response to screen: ESU filter out: 0.5 to 40 Hz, -3 db max @ 1 mVpp input ESU filter in:...0.5 to 20 Hz, -3 db max @ 1 mVpp input Heart Rate Meter: Range:..30-300 bpm adult/child. 30-350 bpm neonatal Accuracy:.......30-250 bpm ??3 bpm or 3% whichever is greater Pacer rejection: rejects all pulses of amplitude ??2.0 mV to ??700 mV and duration 0.1 ms to 2 ms with no tail. Rejects all pulses ??2.0 mV to ??700 mV and duration 0.1 ms to 2 ms with 100 ms T.C tail <0.8 mV or 25 ms T.C tail <0.4 mV. Display update:.................................2 seconds ??0.1 sec NIBP: Technique:....................................................oscillometric Systolic range:................adult/ped mode: 50-250 mmHg neonate mode: 15-150 mmHg. Diastolic range: adult/ped mode:..............30-200 mmHg Systolic accuracy: mean error less than 7 mmHg, stan- dard deviation less than 8 mmHg (adult/pediatric) Mean error less than 3 mmHg, standard deviation less than 13 mmHg (neonatal). 3915 152nd St NE | Marysville, WA 98271 | 1.800.827.3747 Specifications (continued): Diastolic accuracy:....mean error less than 7 mmHg, standard deviation less than 8 mmHg (adult/pediatric) Mean error less than 4 mmHg, standard deviation less than 7 mmHg (neonatal) Heart rate meter range:..............................................................................30-250 bpm Heart rate meter accuracy:..................................??3 bpm or ??3% whichever is greater Pulse Oximetry: Accuracy (1 standard deviation):...70-100%, ??2%: 60-69%, ??4%: 0-59%, unspecified Response time: 13 seconds to 95% of final step change % SpO2 value from 60-95% at 72 bpm Recorder (optional): Speed:..............................................................50, 25, 12.5, 6.25, 3.125 mm/sec ??5% Note:.....................6.25 and 3.125 are for respiration only. Chart size: 50 mm ??2 mm Battery Requirements: 2 sealed lead acid batteries Voltage: 12 VDC. Capacity: 2.3 AH each Run time: 2 hours fully charged battery Recharge time: 16 hours maximum Low battery warning: 11.6 ??3.5% Low battery cut off: 11.0 ??2.8%

$880.00 - details »
Medtronic Lifepak Defibrillator

This is an excellent Medtronic Lifepak Defibrillator. In excellent working and cosmetic condition!

$600.00 - details »
PhysioControl Lifepak 10

PhysioControl Lifepak 10 Defibrillator

Online Pricing Not Available - details »

 
« Previous 1 Next »
Winner of the DOTMed Top 100 Award
H+H Surgical Technologies
4437 Robertson Road
Madison, WI 53714
608.222.2776
 

© Copyright 2012 H & H Surgical Technologies, LLC
Web Design and Hosting by Amplify Internet